Biological safety cabinet bsc class ii a2 b2 nsf en12469 introduction a class ii biological safety cabinet bsc is a ventilated containment device found in laboratories around the world.
Biological safety cabinet class 2 a2.
There are five types.
Esco labculture class ii type a2 biological safety cabinet e series blends the latest generation of energy efficient dc ecm motor technology with esco s experience of more than 25 years in biosafety cabinet design.
Type a1 formerly a type a2 formerly a b3 type b1 type b2 and type c1.
Bscs are used in many applications including cell culture pharmaceutical clinical and microbiological work.
The labculture combines a multitude of design construction and proprietary technological considerations to provide optimum.
The axiom is an r d 100 awards for innovation finalist.
For all class ii bscs except the nu 435 total exhaust biological safety fume hood which has been evaluated by ul and classified to the ul 1805 fume hood standard for use with volatiles nuaire places a bright red warning label on the face of the cabinet concerning the use of flammables as follows.
These energy efficient cabinets provide both personal and product protection from biological hazards and contamination and can be connected to external exhaust to provide protection for volatile toxic chemicals used in the cabinet.
As the pioneer and leading innovator of air containment contamination control and precision cell culture products baker doesn t take shortcuts when it comes to protecting you or your research.
They may exhaust hepa filtered air back into the lab or may be exhaust outside using a canopy connection.
Nuaire class ii type a2 biological safety cabinets offer personnel product and environmental protection to obtain optimum control over product quality while reducing the potential for exposure of both product and personnel to airborne biological or particulate chemical agents in low to moderate risk hazard research and drug preparation or product operations.
Our high performance laboratory equipment is built with you in mind with industry leading.
The purifier axiom class ii type c1 is the first biological safety cabinet that can be used in a recirculating type a mode for standard microbiological work or can be connected to an exhaust system to function in type b mode for handling hazardous chemical vapors or radionuclides.
A class ii biosafety cabinet used for handling leishmania class ii cabinets provide both kinds of protection of the samples and of the environment since makeup air is also hepa filtered.
Class ii type a2 biosafety cabinet.
A class ii type a1 cabinet must maintain a minimum average inflow velocity of 75 fpm through the sash opening.